Infant Incubator BK-3201
BK-3201
Short Description:
Features:LCD displayDouble control modes of bed temperature and skin temperatureDouble-layer thermostatic cover, automatic air curtain deviceHumidity control functionAir & Oxygen blenderOxygen supply systemBaby cot is infinitely adjustable24 kinds of sound and light alarm, comprehensive protection of baby safetyTechnical parameters:General parametersItemSpecificationsPower supplyAC220V,50/60Hz(Standard) 1320VA; 110V 60Hz(Optional)Size(L*W*H)950*645*(1250-11450) mmMaximum heater output power(220VAC)Air chamber heater:330W; Water tank heater:155WAuxiliary network power outputAC220V/50Hz, both maximum permissible currents are 220V 1.5AHeater indication0~100%, 10% increasing amountTemperature control modeBed temperature mode; skin temperature modeBed temperature control range25.0~37.0℃; 37.1~39.0℃(Span mode)Skin temperature control range34.0~37.0℃;37.1~38.0℃(Span mode)Skin temperature sensor display range5.0~65.0℃Heating time≤ 50minTemperature variability≤ 0.5℃Temperature uniformity (mattress in horizontal position)≤ 0.8℃Temperature uniformity (mattress in tilted position)≤1.0℃Difference between average incubator temperature and control temperature≤1.5℃Skin temperature sensor accuracy±0.3℃Humidity controlThe running time of the tank after it is filled with distilled waterHumidity below 70%RH, at least 24hWater tank capacity1500mlHumidity display range0%RH~99%RHHumidity control rangeCAH%RH~90%RH(1% per adjustment)Humidity control accuracy±10%Oxygen concentration controlOxygen concentration display range0%~99%Oxygen concentration display resolution1%Oxygen concentration control accuracy±5% oxygen volume concentrationOxygen concentration setting range21% ~ 60% (1% per adjustment)Oxygen sensor service lifeThe maximum use time is 10000h at 100% oxygen concentrationTransport storageTemperature-20℃~+55℃Atmospheric pressure range500hPa~1060hPaRelative humidity≤93%RHPacking size/ Gross WeightBase packing size: 1200*800*870mm 50KgBody packing size: 1100*710*855mm 60KgThe work environmentRelative humidity30%RH~75%RHEnvironment temperature+20℃~+30℃Pressure range700hPa~1060hPaService altitude≤2000mOvervoltage categoryⅡPollution level2Ambient air velocity≤ 0.3m/sOther indicatorsAmbient noise in the infant compartment of the incubatorNo more than 55dB(A) at stable temperatureCarbon dioxide concentration in the infant compartmentA mixture of 4% carbon dioxide and air was fed into an 8mm diameter tube in the vertical direction from the mat to the top of the box at 750mL /min to a point 10cm above the mattress center and 10cm above the center. The concentration was less than 0 5% after stabilizationThe velocity of air flow over the baby mattress≤0.35m/sGeneralalarmPower failure alarm, fan alarm, sensor alarm, deviation alarm, over temperature alarm, water tank placement error alarm, water shortage alarmSystem alarmMcu1 and Mcu2 communication error alarm, Mcu2 and Mcu3 communication error alarm, analog-to-digital conversion chip 2544 failure alarm, analog-to-digital conversion chip 2548 failure alarm, over temperature alarm, temperature heating system failure, humidity heating system failureConfiguration:ModelBK-3201(I)BK-3201(II)Temp. ControlBed/Skin temperatureBed/Skin temperatureDisplayLCDLCDBed Temp. Control Range25℃-39℃25℃-39℃Skin Temp. Control Range34℃-38℃/Humidity Control RangeCAH%~99%RHCAH%~99%RHOxygen Control Range21%-99%/CabinetYesYes
Send email to us
Download as PDF

Leave Your Message